Home · Blog · Release notes

BrixDEM 1.1: truer contact physics, simpler calibration and new equipment

🚀 Release notes · Jul 20, 2026 · 7 min read

BrixDEM version 1.1
BrixDEM 1.1 puts the work where it shows up in the result: the contact physics that governs how material piles up and comes to rest, the calibration that ties the model to the real test, and the path between drawing the equipment and watching the simulation run. The changes span the solver, calibration, Sketch and the interface — summarised below and listed in full at the end.
Quick summary: reworked rolling and twisting resistance models, rebuilt angle-of-repose calibration, continuous mass flow with particle size distribution (PSD), coarse-graining with a linear model, ribbon and paddle mixers in Sketch, and solver switching without stopping the run.

Contact physics: rolling and twisting reworked

Rolling and twisting resistance are what separate a pile that collapses from a pile that holds the right angle. In 1.1 this part of the solver was rewritten with two goals: keep only the models that behave well numerically, and make each parameter's effect predictable.

  • Rolling resistance: the elastic–plastic (EPSD) and viscous models were improved, with consistently bounded torque and better stability at larger time steps.
  • Twisting resistance: the spring and viscous models were removed, and the remaining formulation now follows Marshall — a single, well-defined and validated implementation instead of three overlapping alternatives.

Calibration: less trial and error

Automatic calibration received the deepest revision in this release. The critical point was angle-of-repose detection: the previous method was sensitive to pile shape and could return unstable angles between runs. The new detection method measures the angle more robustly, and the result repeats.

  • Test settings inside calibration: the experiment variables — geometry, material quantity, duration — are now part of the calibration case instead of being implicit.
  • Parameters easier to change: adjusting and re-running a calibration no longer means rebuilding the case.
  • Cohesion tuned per test: cohesion is now handled coherently with the chosen protocol, rather than as a single value shared across every test.

The corresponding theory in the user guide was revised to match.

Continuous feed with real size distribution

Transfer chutes, conveyors and elevators rarely run on a one-off injection: they receive material at a constant mass flow rate, with a distribution of sizes. Version 1.1 brings continuous mass flow with PSD — you specify the mass rate and the size distribution, and the injector holds that regime throughout the simulation.

Alongside it comes coarse-graining with a linear model: representing the material with particles larger than the real ones, with contact parameters scaled consistently, so industrial-scale equipment can be simulated in a workable amount of machine time.

Sketch: ribbon and paddle mixers

The built-in modeler gained two complete pieces of equipment, assembled from parameters rather than drawn by hand:

  • Ribbon mixer (helical ribbon blender), typical of powders and food processing.
  • Paddle mixer, common in animal feed, fertilizers and mortars.

The union and vortexization operations were also improved, producing cleaner solids from complex profiles — which cuts geometry rework before simulating.

Interface: less friction while working

Three changes affect the rhythm of daily use more than their size suggests:

  • Switch the solver during a run: changing the solver from the GUI while the simulation is running is now possible, with no case rebuild.
  • Motions keep what you filled in: saving a motion preserves the fields set beforehand instead of resetting them to defaults.
  • Leaner left panel: clicking the geometry shows the corresponding STL or surface directly, without navigating the tree.

Image and video quality

Visual output is what leaves your workstation and reaches the report or the presentation. Version 1.1 improves the quality of generated images and videos and gives direct control over scene lighting, with adjustable light azimuth and elevation and uniform ambient light — enough to bring out material relief and the inside of the equipment without external post-processing.

Full list of changes

Solver and contact models

  • Improved elastic–plastic (EPSD) and viscous rolling resistance models.
  • Removed spring and viscous twisting models; improved Marshall formulation.
  • Cohesion converted into a toggleable model, like rolling and twisting resistance.
  • Coarse-graining with a linear model, adjusted.
  • Solver switching from the GUI during a run.

Calibration

  • New angle-of-repose detection method.
  • Test variable settings incorporated into the calibration case.
  • Easier parameter changes and re-runs.
  • Cohesion tuned specifically per test.
  • Revised user guide theory.

Injection and materials

  • Continuous mass flow with particle size distribution (PSD).

Sketch and geometry

  • Ribbon mixer and paddle mixer available as equipment.
  • Improved union and vortexization operations.
  • A–A self-intersection check removed from the inspection flow.

Results and post-processing

  • Adjustments and improvements to the Lacey mixing index and concentration CV results.

Interface and visualization

  • Improved quality of generated images and videos.
  • Light azimuth and elevation control.
  • Uniform ambient light across the scene.
  • Saving a motion keeps previously filled fields.
  • Reduced left panel, showing STL or surface when clicking the geometry.
  • General interface design adjustments.

How to update

Version 1.1 replaces the previous installation: download the installer from the download page and run it as usual. .brixdemproject files created in the previous version still open. Cases that used the spring or viscous twisting models now use the Marshall formulation and should be recalibrated before comparing results with older runs.

Run 1.1 on your own equipment

BrixDEM is free to download and runs on Windows. Open an example case and see the new models in action.

Back to blog