CHAPTER 20

Best Practices

Principles and working habits for experienced DEM users.

20.1 Units

Use International System (SI) where possible:

QUANTITY SI UNIT
Length m
Density kg/m3
Time s
Speed m/s
Young’s modulus Pa
Force N
Torque N·m
Angular velocity rad/s

When using Sketch in mm or cm, confirm the conversion before exporting to simulation.

Respect units shown by each form: liquid viscosity is entered in mPa·s, breakage reference size in mm, and energy may mean J or J/kg, depending on the model. Convert once and record the basis to avoid errors by a factor of a thousand or by a factor of particle mass.

20.2 Timestep

Start conservatively. A small timestep costs performance, but a large timestep invalidates the entire simulation. Whenever possible, do sensitivity studies comparing results with smaller Δt.

For breakage, check the suggestion already shown by the GUI and apply it deliberately (12.6). Fragments smaller than the rebreakage cutoff may be born; check the predicted size when choosing the step.

20.3 STL mesh

Use mesh sufficiently smooth for contact to be well captured, but without excess. Details smaller than particle diameter rarely justify the additional computational cost.

20.4 Materials

Always keep the distinction between material property (ρ, E, ν - intrinsic to the body), interaction between materials (en, μ, μ r - pair-by-pair) and calibrated parameter (a value fitted to a specific test, possibly different from the literature value). Don't confuse physical elastic modulus with effective numerical stiffness when using simplifications such as reducing E to accelerate simulation.

Separate contact verification from process calibration: first check a bridge between spheres or isolated breakage using Appendix H cases, then calibrate/validate the real material as in Chapter 18. Check 28.7 before combining models. For coarse-graining, compare against the fine case and inspect the E control in 10.7 rather than assuming equivalence from one conserved parameter.

20.5 Results and traceability

For each simulated case, archive: project configuration; main CSVs (energy, forces, flow); solver logs; final images and graphics; software version (BrixDEM build); and observations on the parameters changed relative to the baseline.

Keep a baseline - Create a folder 00_baseline in the project directory with the reference case and never modify it. Every variation stays in folders 01_…, 02_… etc. This preserves traceability between versions and facilitates auditing.

Choose particle-output cadence to resolve the events being studied. Record surface content and liquid properties, breakage family and parameters, energy convention, seed, CGF and E options. Unsaved fields cannot be rigorously reconstructed from animation; a sampled graph may miss the impact peak.