CHAPTER 29

Surface Wear - Practical Use

How to activate, parameterize and interpret the estimated wear in geometries. The physical foundation (Archard and Oka) is in Chapter 3.13.

BrixDEM estimates surface wear (chutes, liners, paddles, screens) from particle-wall contacts, accumulating the depth removed [m] per mesh triangle. Two mechanisms can be activated separately or together: abrasive (Archard, sliding) and impact erosion (Oka). The equations are in Chapter 3.13.

29.1 Enable and parameterize

On the STL surface panel, enable wear and choose the mechanisms. Each has its own parameters:

PARAMETER MODEL MEANING
Enable abrasive / impact both Enable each mechanism independently
Abrasive coefficient (K/H) Archard Specific wear coefficient [1/Pa]
Vickers hardness H_v Oka Hardness of surface material [GPa]
n1, n2 Oka Exponents of the angular function g(α)
k1, k2, k3 Oka E90 hardness, speed and diameter exponents
v ref, d ref Oka Reference speed and diameter

29.2 Standard reference values (Oka model)

BrixDEM already comes with a standard set of Oka literature values (2005), a reasonable starting point before calibrating against field data:

PARAMETER STANDARD VALUE OBSERVATION
k2 (speed exponent) 2.3 Erosion sensitivity to impact speed
n1 (angular exponent) 0.8 Shape of the angular dependence
n2 (angular exponent) 1.0 Hardness term in the angular function
v ref (reference speed) 104 m/s Oka test normalisation speed
d ref (reference diameter) 326 μm Oka test normalisation diameter
k1, k3 (hardness, diameter) 0.0 Off by default; enable after calibrating for a specific material
Abrasive coefficient K/H Abrasive wear starting point; calibrate for each material
Calibrate before quantitative use - Default values produce a reliable relative map (where it wears most). For an absolute prediction of wear rate or service life, calibrate H_v, K/H and the Oka exponents against wear tests of the real material–coating pair.

29.3 Interpret results

The total wear of each triangle is the sum of the abrasive and impact contributions. The best reading is the spatial distribution: color the surface by the accumulated depth to locate the areas of greatest attack - where to reinforce the liner, change a chute angle or reposition an impact point. The statistics reported include minimum, maximum, sum and average per triangle.

Use wear to compare designs - The main strength of DEM wear prediction is comparative: Run two chute geometries or two liner angles and compare the map and peak wear. For the average, remember that it is a simple mean per triangle (Chapter 28.2); the maximum and map are the most robust indicators.

29.4 Wear under Elevator motion (multiple copies)

The Elevator motion (7.5) replicates a single STL - the body attached to that motion, whether it is a bucket, a paddle, or any other part - into several copies along the closed loop. In the solver, each copy of the body accumulates its own wear, independently. But in the visualization and in the wear-over-time graph, all copies of the same Elevator are combined into a single displayed instance, using the per-triangle maximum across all copies.

In practice, this means: if you have an Elevator with several copies of the body and look at the wear map or graph, you are seeing the worst case across all copies projected onto a single instance - not the sum, not one specific copy, and not an average. This is intentional (it avoids N identical graphs for N copies of the same part) and is not a physics error: the per-copy calculation in the solver remains correct and independent.

Multiple different STLs in the same case - if your case combines the Elevator with other STLs that do not use Elevator motion (for example, a stationary housing or discharge chute), those other bodies do not take part in this combination - each keeps its own wear map and graph, independent from each other and from the Elevator. The max-combine only applies to the internal copies of a single body under Elevator motion.